REGISTRATION FORM

Personal


Enter your name and surname

Enter the company you belong to

Enter the postal code

The Postal Code must be numeric

User


Enter a valid email

Please enter a password of at least 6 characters

The password field does not match

I have read and accept the

You have to fill in the fields correctly

Thank you for registering with Hitecsa, we have sent you an email for validation. Once validated you will be able to identify yourself to download all our technical documents.

LOGIN

You have to enter a valid email

You have to enter the password

Don't you remember the password?

You must be registered to download our documents. if not, you can do it in a minuteSign up

I FORGOT MY PASSWORD

Enter the email address associated with your account and we will send you instructions to reset your password.

You have to enter a valid email

Username does not exist

We have sent an email with a link to change your password to the email address you have provided.

You are in: Products / Industrial Series

Industrial Series

KRONO 2 HE
EKWXBA HE Air-Water

Reversible monobloc heat pumps with air condensation and axial fans. Series of hermetic scroll-type rotary compressors and refrigerant gas R410A.

TECHNICAL DATA

• Cooling capacities: 37.9 to 206.5 kW
• Heating capacities: 42.3 to 242.3 kW
• Compressors: 2 or 4 compressors, depending on model, hermetically sealed scroll-type rotary compressors with thermal protection and crankcase heater
• Electronic expansion valve on models 75.2 / 95.2 / 109.2 /171.4 / 193.4 / 207.4
• Water Side Exchanger: thermally insulated Stainless Steel Plates
• Air-side heat exchanger: aluminium finned coil with copper tubes
• Fans: 2, 3, 4 or 6 fans, depending on models, axial-type impeller with brushless EC motor and internal thermal protection; protection grilles; proportional electronic device for continuous regulation of the fan rotation speed (condensation control + evaporation control)
• 1 or 2 water circulation pumps integrated into the unit (depending on models)
• Control: electronic microprocessor
• Outside temperature probe allowing compensation of the setpoint value (functional up to model 109.2; for information purposes only in all others)
• Modbus integrated as standard
• Master/Slave management up to 4 units in parallel
• Magnetothermic switches in compressors and fans
• Structure: galvanised and painted sheet steel
• Compressor sound insulation as standard up to model 55.2

VERSIONS
• Heat pump
• Cooling only (optional)
• No circulation pump (optional)